4-8

IM WX13-01E

Circular Monitor

You can display one hour to four weeks worth of data on a circular graph. On the circular

graph, the radius corresponds to the Y-axis of the trend display, and the circumference

corresponds to the time axis.

Select the displayed group

Alarm ON/OFF

Channel No., Tag No., or Tag Comment

The red bar blinks when an alarm occurs.

Current waveform mark

Zone display area

Waveform display ON/OFF

Date

Absolute or

relative time

Alarm indication

Displayed time per cycle

Brightness adjustment

knob of the waveform

display area

Grid brightness

adjustment knob

Show/Hide zone

display area

Zoom In or Zoom Out of the time axis

Waveform display zone

Display Cursor’s Value

Circular display channel

Select the current waveform

When monitor paused

Cursor

When the monitor is paused

Move the waveform display position (Scroll bar).

For the operating procedures listed below, see section 4.3, “Changing the Waveform

Display.”

For operations using the cursor, see section 4.4, “Using Cursors.”

• Using the waveform display zones (user zone, edit zone, full zone, slide zone, auto

zone, multi-axis zone).

• Showing/hiding alarms.

• Specifying the thickness of the waveform display lines.

• Changing the time axis display (absolute or relative).

• Adjusting the brightness of the waveform display area and grid.

• Using cursors.

4.1 Displaying Waveforms on Monitor Screens