Yokogawa DAQWORX User Manual
Page 76

4-16
IM WX13-01E
• User Zone
Displays the waveform using the zone specified in the General Display Settings.
• Edit Zone
You can change the zone in the zone display area of the trend monitor screen.
In the zone display area, drag the slider at the top and bottom ends of the zone bar
to change the zone. The zone setting specified in the zone display area is reflected in
the General Display Settings dialog box.
Zone bar
Top adjustment knob
Bottom adjustment knob
• Full Zone
Assigns a full zone to all the displayed waveforms.
• Slide Zone
The zone width of each waveform is made equal, and the start position of the display
zone is offset slightly for each waveform.
• Auto Zone
Displays the waveforms by equally dividing the waveform display area according to
the number of displayed waveforms.
4.3 Changing the Waveform Display