The electronic lock combination consists of six digits. Upon arrival, the combination of the lock should already be set
at 1-2-3-4-5-6. After installation on the safe has been completed, enter the preset combination and check for proper
operation. After each keypress, the lock will beep. After the final digit has been entered, the lock will beep twice, and
the open period will begin. When a valid combination has been entered, the operator will have approximately 3
seconds to open the lock. To open the lock, turn the dial clockwise. After the lock is opened, the door latch may be
turned and the safe opened.

C

HANGING

THE

C

OMBINATION

To change the combination of the lock, simply follow these directions.

·1.) Enter six zeros.
·2.) Enter the current combination. (Initially set at 1-2-3-4-5-6)
·3.) Enter the new combination twice.
·4.) The combination is now chanced. Enter the new combination to open the lock.

L

OCKOUT

F

EATURE

The electronic lock includes a WRONG TRY PENALTY lockout feature that prevents entry from unauthorized per-
sonnel. This feature performs as follows and CANNOT be disabled:

·1.) Entry of four consecutive invalid combinations will disable the lock for 5 minutes. During this period, the panel

LED will flash every 10 seconds. During this time the lock will remain closed and no other combination entries
will be allowed.

·2.) At the end of the lockout period, if two more consecutive invalid combinations are entered, the 5-minute lockout

period will restart.

B

ATTERY

R

EPLACEMENT

Repeated beeping while the lock is open indicates that the 9 volt battery, located in the battery box on the inside of the
door, needs to be replaced. To remove the battery box cover, pull gently on the front of the box and slide the cover off.
If the lock will not operate while the door is closed and locked, (i.e. no signal from the panel when a button is pressed),
the battery is dead and the lock will need to be energized from the two round jumper terminals located on the front,
right side of the push-button panel. To energize the lock, connect a 9-volt battery across the external terminals with the
negative terminal of the battery facing up. While holding the battery against the terminals, enter the six-digit combi-
nation and open the lock and door. Replace the battery inside the battery box.