2.2.2.2 Control connections for SK TU4-DEV(-…)

The double spring-loaded terminal bar of the technology unit is colour coded, and therefore indicates the three
different potential levels.
A separate voltage source can be used to supply the DOs. However, by bridging the 24V o and GND o to one
of the terminals of the system bus level 24V and GND it is possible to implement the supply of the DOs.
Connection of up to 4 sensors and 2 actuators is made via the terminal bar. Alternatively, the
SK TU4-DEV-M12 module enables the connection of these I/Os via the M12 round plug connector (5 pin
socket, A-coded) mounted on the front.

Field bus level

DeviceNet

System bus level and digital inputs

Digital outputs

24V

BUS

DVN +

IN

DVN -

IN

GND

BUS

SHLD

24V

24V

(as for 11)

GND

GND

DIN 1

GND

24V

(as for 11)

DIN 2

DIN 4

24V

(as for 11)

24V

O

DO

DO 1

GND

O

DO

1

3

5

7

9

11

13

15

17

19

21

23

25

27

29

31

33

35

2

4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

24V

BUS

DVN +

OUT

DVN -

OUT

GND

BUS

PE

24V

(as for 11)

Sys +

Sys -

GND

DIN 3

GND

24V

(as for 11)

DIN 4

GND

24V

(as for 11)

GND

O

DO

DO 2

GND

O

DO

Connection example: SK TU4-DEV to SK 200E

SK205E… - connection unit (SK TI4...)

SK TU4-CAO… - connection unit (SK TI4-TU-BUS)

Voltage

source

24V DC

DeviceNet

participant

X-1

Voltage

source

24V DC

DeviceNet

participant

X+1

Advertising