NORD Drivesystems BU0280 User Manual

Page 40

Advertising
background image

Supplementary Manual DeviceNet for NORDAC SK 200E

40

Subject to technical amendments

BU 0280 GB

4.2.5

Generation of variable data lengths in Instance 120/130

If parameter P160 is set to 0, the structure of the Instance can be freely defined via parameters P161 to P165.
The length of the output and input data does not need to be identical.

Para

Index [0]

Index [1]

Index [2]

Bus

module

P161

Input length

Output length

- - -

FI 1

P162

Status data length

Control data length

Drive profile

FI 2

P163

Status data length

Control data length

Drive profile

FI 3

P164

Status data length

Control data length

Drive profile

FI 4

P165

Status data length

Control data length

Drive profile

Parameter

Value range

Significance

Explanation

P16x [0]

P162-P165 = 0
to 8
P161= 0 to 1

0 = Data length 0 byte
1 = Data length 1 byte
2 – 8 = etc.

Length of status data from FI x
Data length = 0  FI does not exist
Structure:
ZST | IW1 | IW2 | IW3

P16x [1]

P162-P165 = 0
to 8
P161=0 to 1

0 = Data length 0 byte
1 = Data length 1 byte
2 – 8 = etc.

Length of control data for FI x
Data length = 0  FI does not exist
Structure:
STW | SW1 | SW2 | SW3

P16x [2]

P162-P165 = 0
to 2

0 = AC-Drive profile 1

Profile used by FI x on the DeviceNet bus

1 = AC-Drive profile 2
2 = NORDAC profile

Example:

P161 = {1,1}

Inputs/Outputs of the bus module

P162 = {8,8,2}

Control/Status word and 3 Setpoint/Actual value in the NORD-AC profile for FI 1

P163 = {4,8,2}

Control/Status word and 1 setpoint and 3 actual value in the NORD-AC profile for FI 2

P164 = {4,4,0}

1 Setpoint/Actual value in AC drive profile for FI 3

P165 = {0,0,0}

FI 4 is not accessed

Input data length for the bus module: 21 Byte

Output data length for the bus module bytes: 17 Byte