NORD Drivesystems BU0280 User Manual

Page 32

Advertising
background image

Supplementary Manual DeviceNet for NORDAC SK 200E

32

Subject to technical amendments

BU 0280 GB

3.1.2.3 I/O Displays

The status of additional digital inputs and outputs on the BUS module is indicated by corresponding LEDs
(except for SK TU4-DEV(-C)).

I/O Channel

Status display

Significance

Customer Unit SK CU4-DEV

LED (green)

Digital input 1

D1

ON

High

potential on terminal C1

OFF

Low

potential on terminal C1

Digital input 2

D2

ON

High

potential on terminal C2

OFF

Low

potential on terminal C2

Technology unit SK TU4-DEV-M12(-C)

LED

(yellow)

Digital input 1

DI1

ON

High

potential on terminal 19 or on M12 socket DI1

OFF

Low

potential on terminal 19 or on M12 socket DI1

Digital input 2

DI2

ON

High

potential on terminal 25 or on M12 socket DI2

OFF

Low

potential on terminal 25 or on M12 socket DI2

Digital input 3

DI3

ON

High

potential on terminal 20 or on M12 socket DI3

OFF

Low

potential on terminal 20 or on M12 socket DI3

Digital input 4

DI4

ON

High

potential on terminal 26 or on M12 socket DI4

OFF

Low

potential on terminal 26 or on M12 socket DI4

Digital output 1

DO1

ON

High

potential on terminal 33 or on M12 socket DO1

OFF

Low

potential on terminal 33 or on M12 socket DO1

Digital output 2

DO2

ON

High

potential on terminal 34 or on M12 socket DO2

OFF

Low

potential on terminal 34 or on M12 socket DO2

Advertising