HP ProLiant BL10e G2 Server Blade User Manual

Page 136

Advertising
background image

Setting Up the System

3. If your Linux server blade uses LILO:

a. Remove the “message=” file specification from /etc/lilo.conf.

IMPORTANT: Step a is necessary because the remote console of the Integrated
Administrator is text-based, and the message file may be graphical.

b. Add the following line to the ‘linux’ image specification in /etc/lilo.conf:

append “console=tty0 console=ttyS0,115200”

CAUTION: Be sure the text in step a is indented in the file.

c. Run /sbin/lilo to be sure that your changes take effect and continue with

step 5.

4. If your Linux server blade uses GRUB, add the following line to the ‘linux’

image specification in /etc/grub.conf:

append “console=tty0 console=ttyS0,115200”

CAUTION: Be sure the text in step 4 is indented in the specification.

5. Add the following line to the end of /etc/inittab:

7:12345:respawn:/sbin/agetty 115200 ttyS0 vt100

6. Set “SAFE=yes” in the file /etc/sysconfig/kudzu.

7. Add the following line to /etc/securetty to allow root login on the serial console:

ttyS0

After rebooting, the server blade is accessible remotely using the Integrated
Administrator.

HP ProLiant BL e-Class Integrated Administrator User Guide

5-21

HP CONFIDENTIAL

Writer: Hilary Stead File Name: f-ch5 Setting Up the System.doc

Codename: Halo Part Number: 249070-005 Last Saved On: 3/1/04 10:50 AM

Advertising
This manual is related to the following products: