HP ProLiant BL10e G2 Server Blade User Manual

Page 160

Advertising
background image

Performing Common Administrative Tasks

To obtain the enclosure information using the CLI, enter the following commands as
needed:

SHOW ENCLOSURE FAN [<fan number> | ALL]

IMPORTANT: This command displays the status, redundancy, partner, speed, and part
number for one or all fans in the enclosure.

SHOW ENCLOSURE INFO

IMPORTANT: This command displays the enclosure name and enclosure type; the
software and hardware version of the Integrated Administrator; the part number, serial
number, and asset tag number of the enclosure; the MAC address of the Integrated
Administrator; and the type, part number, and serial number of the interconnect tray.

SHOW ENCLOSURE POWERSUPPLY [<power supply number> | ALL]

IMPORTANT: This command displays the status, AC input status, capacity, input voltage
range #1 (Volts), input voltage range #2 (Volts), input frequency range (Hz), part number,
serial number, and hardware revision for one or all power supplies in the enclosure.

SHOW ENCLOSURE STATUS

IMPORTANT: This command displays the status of enclosure health, Integrated
Administrator health, and the Unit Identification LED under the heading “enclosure status,”
and displays the status and capacity of the power supplies of the enclosure under the
heading “power status.”

SHOW ENCLOSURE TEMP

IMPORTANT: This command displays the location, status (OK, warm, degraded, or
failed), and temperature (degrees Fahrenheit and Celsius) for all the temperature sensors
of the enclosure.

HP ProLiant BL e-Class Integrated Administrator User Guide

6-15

HP CONFIDENTIAL

Writer: Hilary Stead File Name: g-ch6 Performing Common Administrative Tasks.doc

Codename: Halo Part Number: 249070-005 Last Saved On: 3/1/04 10:52 AM

Advertising
This manual is related to the following products: