Command Line Interface

Table 4-5: Enclosure Management Commands

continued

Command Description

Restrictions

SHOW
ENCLOSURE
POWERSUPPLY
[<power
supply
number> |
ALL]

Displays the power supply status, AC
input status, capacity, input voltage
range #1 (measured in Volts), input
voltage range #2 (if necessary,
measured in Volts), input frequency
range (measured in Hertz), part
number, serial number, and hardware
revision for the specified power supply
if one is specified or for all power
supplies if ALL is given.

None

SHOW
ENCLOSURE
STATUS

Under an enclosure status heading,
this command displays the health,
Integrated Administrator health, and
unit identification LED of the enclosure.

Under a power status heading, this
command displays the power status
and capacity.

None

SHOW
ENCLOSURE
TEMP

Displays the locale, status (OK, warm,
degraded, or failed), temperature in
degrees Fahrenheit, and temperature
in degrees Celsius for all temperature
sensors.

None

SHOW RACK
NAME <rack
name>

Shows the name for the rack where the
enclosure resides.

The default rack name is
“UnnamedRack.”

None

SHOW SYSLOG
ENCLOSURE

Displays the syslog of the enclosure
with 22 lines per screen.

Typing “q” q uits the command; any
other key shows the next screen if
more information exists to display.

Typing “c” cont inuously displays the
System Log without page breaks.

Only enclosure administrators
may execute this command.

SHOW TRAY
INFO

Displays the manufacturer, product
name, part number, serial number, and
spare number of the interconnect tray.

None

continued