Table 4-5: Enclosure Management Commands
continued
Command Description
Restrictions
SET DATE
MMDDhhmm
{{CC}YY} {TZ}
Sets the date of the enclosure with the
following definitions:
•
MM: month
•
DD: day
•
hh: hour (24-hour time)
•
mm: minute
•
CC: century
•
YY: year
•
TZ: time zone (case-sensitive)
If the time zone is left blank, the
current time zone is left in effect.
Only enclosure administrators
may execute this command.
•
MM is an integer from 1-12.
•
DD is an integer from 1-31.
•
hh is an integer from 0-23.
•
mm is an integer from 0-59.
For a list of time zones, see
Appendix F, “Time Zone
Settings.”
NTP must be disabled before
manually setting the date and
time.
SET ENCLOSURE
ASSET {TAG}
<asset tag>
Changes the enclosure asset tag
Only enclosure administrators
may execute this command.
The <asset tag> must be 1-31
characters long and includes
alphanumeric, dash, and
underscore characters.
The default enclosure asset tag
is blank. To set a blank asset tag,
specify the blank value using
quotes.
SET ENCLOSURE
NAME
<enclosure
name>
Changes the enclosure name
Only enclosure administrators
may execute this command.
The <enclosure name> must be
1-32 characters long and
includes all alphanumeric, the
dash, and the underscore
characters.
The default enclosure name is
IA-MAC where MAC is replaced
with the actual MAC address.
continued
HP ProLiant BL e-Class Integrated Administrator User Guide
4-17
HP CONFIDENTIAL
Writer: Hilary Stead File Name: e-ch4 Command Line Interface.doc