Introduction 10

# Add uplink ports to the networks
add uplinkport enc0:1:1 network=MyNetwork
add uplinkport enc0:1:2 network=Network2

# Create a Shared Uplink Port Set
add uplinkset SharedSet1

# Add a new FCoE SAN fabric connection to a profile
add fcoe-connection MyNewProfile Fabric=SAN_5

# Reset the active QoS configuration type to the factory default settings but

does not change the saved configuration types
reset qos -active

# Set the domain default LACP timer to the short setting (one second)
set lacp-timer default=Short

# Add a Multicast Filter "filter1" to Filterset "mfs1"
add mfs-filter FilterSet=mfs1 McastFilter =filter1

# Set the global option to enable the loop protection and pause flood protection
set port-protect networkLoop=Enabled PauseFlood=Enabled

# Set idle user sessions to expire after 20 minutes of inactivity
set session Timeout=20

# Create a new Multicast Filter and adds it to the domain
add mcast-filter MyMcastFilter

# Assign a profile to a device bay
assign profile MyProfile enc0:1

# Done!!!