HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual

Page 192

Advertising
background image

Configuring the Virtual Connect domain using the CLI 192

2

Start with modules in Bays

3–6, create a profile, then

edit the profile and add
connections.

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 5

4

Bay 6

Bay 3 Bay 4

Bay 5 Bay 6

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 5

4

Bay 6

5

Bay 3

6

Bay 4

7

Bay 5

8

Bay 6

Add connection, 4 times

3

Start with modules in Bays 3

and 4, create a profile,

install modules into Bays 5
and 6, then edit the profile

and add connections.

Port

Connected to

1

Bay 3

2

Bay 4

Bay 3 Bay 4

Bay 5 Bay 6

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 5

4

Bay 6

Add connection, 2 times

4

Start with modules in Bays 3
and 4, create a profile (add

2 connections), install

modules into Bays 5 and 6,
then edit the profile.

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 3

4

Bay 4

Bay 3 Bay 4

Bay 5 Bay 6

Add connection is disallowed
because the current FC module

configurations do not match

the existing connections in the
profile.

This profile is not useful after

the hot-plug install. To resolve
this issue, delete connections 3

and 4, save the profile, and

then scenario 3 applies.

5

Start with modules in Bays
3–6, create a profile, install

modules into Bays 7 and 8,

then edit the profile and add
connections.

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 5

4

Bay 6

Bay 3 Bay 4

Bay 5 Bay 6

Bay 7 Bay 8

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 5

4

Bay 6

5

Bay 7

6

Bay 8

Add connection, 2 times

6

Start with modules in Bays

3–6, create a profile (add 4

connections), install modules
into Bays 7 and 8, then edit

the profile.

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 5

4

Bay 6

5

Bay 3

6

Bay 4

7

Bay 5

8

Bay 6

Bay 3 Bay 4

Bay 5 Bay 6
Bay 7 Bay 8

Add connection is disallowed

because the current FC module

configurations do not match
the existing connections in the

profile.

This profile is not useful after
the hot-plug install. To resolve

this issue, delete connections

5–8, save the profile, and then
scenario 5 applies.

7

Start with modules in Bays 5

and 6, create a profile,

install modules into Bays 3
and 4, then edit the profile.

Port

Connected to

1

Bay 5

2

Bay 6

Bay 3 Bay 4

Bay 5 Bay 6

Add connection is disallowed

because the current FC module

configurations do not match
the existing connections in the

profile.

To make this profile useful,
remove the two connections,

save the profile, and then

begin adding connections.

Advertising