HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual

Page 125

Advertising
background image

Command line 125

Item

Description

LAGID (optional) The LAG ID on which to display statistics information. The LAG ID is in the format

<EnclosureID>:<BayNumber>:<LagLabel>. LagLabel must be in the format

lagNN, where NN is the LAG number.

PortID (optional) The ID of the port on which to display statistics information. The port ID is in the format

<EnclosureID>:<BayNumber>:<PortLabel>.

Examples

->show statistics enc0:3:X1

Displays statistics for uplink port X1 on interconnect module 3 of the primary enclosure

->show statistics enc0:1:Q1.1

Displays statistics for QSFP+ uplink port Q1.1 on interconnect module 1 of the primary

enclosure

->show statistics enc0:1:d3

Displays statistics for downlink port d3 on Ethernet interconnect module 1 of the

primary enclosure

->show statistics enc0:1:d1:v1

Displays statistics for subport v1 of downlink port d1 on Ethernet interconnect module
1 of the primary enclosure

->show statistics PortID=enc0:1:X1

Displays statistics for uplink port X1 on interconnect module 1 of the primary enclosure

->show statistics -summary LAGID=enc0:1:lag25

Displays aggregated statistics with selected counters for a given LAG ID on

interconnect module 1 of the primary enclosure

->show statistics LAGID=enc0:1:lag25

Displays aggregated statistics for a given LAG ID on interconnect module 1 of the

primary enclosure

In addition to the standard statistics, Virtual Connect also provides additional information on DCBX and QoS.
The QoS statistics are displayed for the specified physical port. The types of QoS statistics are in the format
of cosq<N>_<counter>, where <N> is the queue number with values 0-7. The queue number N is based

on the egress dot1p priority of the corresponding QoS traffic class. When QoS is not enabled, cosq3 is for

FCoE traffic and cosq0 is for regular Ethernet traffic.
The following table lists the types of QoS statistics displayed.

Item

Description

cosq<N>_ucast_OutBytes

The accumulated transmitted byte count of unicast packets of the queue for

the specified port. For VC FlexFabric 10Gb/24-port module and VC

Flex-10 Enet module, the counter is not supported and the value is 0.

cosq<N>_ucast_OutPkts

The accumulated transmitted packet count of unicast packets of the queue
for the specified port. For VC FlexFabric 10Gb/24-port module and VC

Flex-10 Enet module, the counter includes both unicast and multicast data.

cosq<N>_ucast_DroppedPkts

The accumulated dropped packet count of unicast packet of the queue for
the specified port. For VC FlexFabric 10Gb/24-port module and VC

Flex-10 Enet module, the counter includes unicast and multicast data.

DCBX is the data center discovery and capability exchange protocol used by DCB devices to exchange

configuration information with directly-connected peers. The protocol can also be used for misconfiguration

detection and for configuration of the peer. In this release, the VC module adopts the DCBX specification to

implement the control state machine and three feature state machines:

Priority Group (PG)

Advertising