Sflow-ports – HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual
Page 110

Command line 110
Item
Description
->show sflow-module enc0:1
Displays the specified sflow module
sflow-ports
Configure the ports to be sampled or polled for a receiver.
Supported actions: add, help, remove, set, show
Item
Description
add sflow-ports
Add a port to be sampled or polled for a receiver.
Syntax
add sflow-ports <ReceiverName>[SamplePorts=<PortID
list>[SamplingRates=<SamplingRate
list>][Direction=<Ingress|Egress|Both>]][PollPorts=<Port
ID list> [PollingIntervals=<PollingInterval list>]]
Parameter
ReceiverName
(required)
Specifies the unique name of the receiver. A valid receiver name can have a
minimum of one character and maximum of 64 characters. Only alphanumeric
characters, -(hyphen), and _(underscore) are allowed. White spaces are not
allowed.
Properties
SamplePorts (optional) Specifies a list of enet module ports to be sampled for flow samples. The ports
are specified as a comma separated list where each port is in the format
<EnclosureID>:<InterconnectBay>[:<PortNumber1[-PortNumberN]>].
SamplingRates
(optional)
Specifies the statistical sampling rate of packets on a port. Each sampling rate
has a corresponding port in the SamplePorts list. The valid sampling rate can be
an integer from 256 to 16777216. The default value is 4096.
Direction (optional)
Specifies the direction of the network traffic on the port to be sampled. The valid
values are "Ingress", "Egress", or "Both". The default value is "Both".
PollPorts (optional)
Specifies a list of enet module ports to be polled for counter samples. The ports
are specified as a comma separated list where each port is in the format:
<EnclosureID>:<InterconnectBay>[:<PortNumber1[-PortNumberN]>].
PollingIntervals
(optional)
Specifies the polling interval which is the maximum number of seconds between
successive samples of the counters associated with these ports. Each value in the
list of polling interval has a corresponding port in the PollPorts list. The valid
polling interval range is from 1 to 65535 seconds. The default value is "10
seconds". Disable polling on a port using the remove sflow-ports
command.
Configure the module network using the set sflow-module command before
adding the module port for sampling or polling to a receiver.
Examples
->add sflow-ports Alpha
SamplePorts=enc0:1:d1,enc0:2,enc0:1:d3-d10
Samplingrates=256,1024,2048
Direction=IngressPollPorts=enc0:1:d2,enc0:1:d3,enc0:1:d4
PollingIntervals=10,1,5
Adds sample and polling ports
Item
Description
remove sflow-ports
Removes ports from an sflow receiver
Syntax
remove sflow-ports <ReceiverName> [[SamplePorts=<PortID
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric-20.40 F8 Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem