Item
Description
list|*>][PollPorts=<PortID list|*>]]
Parameter
ReceiverName (required) The name of an existing sflow receiver in the domain
Properties
SamplePorts (optional)
Specifies a list of sample ports to be removed from a receiver. "*" removes all
sample ports from the receiver. The ports are specified as a comma separated
list where each port is in the format:
<EnclosureID>:<InterconnectBay>[:<PortNumber1[-PortNumberN]>].
The ID for the sample port can be referenced from the output of the show
sflow-ports command.
PollPorts (optional)
Specifies a list of polling ports to be removed from a receiver. "*" removes all
polling ports from the receiver. The ports are specified as a comma separated
list where each port is in the format:
<EnclosureID>:<InterconnectBay>[:<PortNumber1[-PortNumberN]>].
The ID for the poll port can be referenced from the output of the show
sflow-ports command.
Examples
->remove sflow-ports Alpha
SamplePorts=enc0:1:d1,enc0:1:d3
Removes a sample port
->remove sflow-ports Alpha PollPorts=enc0:1:d1,enc0:1:d
Removes a polling port
->remove sflow-ports Alpha SamplePorts=*
Removes all sample ports
->remove sflow-ports Alpha PollPorts=*
Remove all polling ports
Item
Description
set sflow-ports
Modify a port to be sampled or polled for a receiver.
Syntax
set sflow-ports <ReceiverName> [SamplePorts=<PortID
list>[SamplingRates=<SamplingRate
list>][Direction=<Ingress|Egress|Both>]][PollPorts=<Port
ID list>PollingIntervals=<PollingInterval list>]
Parameters
ReceiverName
(required)
The name of an existing sflow receiver in the domain
Properties
SamplePorts (optional) Specifies a list of VC enet module ports whose sampling rates are to be
modified. The ports are specified as a comma separated list where each port is
in the format:
<EnclosureID>:<InterconnectBay>[:<PortNumber1[-PortNumberN]>].
The ID for the sample port can be referenced from the output of the show
sflow-ports command.
SamplingRates
(optional)
Specifies the statistical sampling rate of packets on a port. Each sampling rate
has a corresponding port in the SamplePorts list. The valid sampling rate can be
an integer from 256 to 16777216. The default value is 4096.
Direction (optional)
Specifies the direction of the network traffic on the port to be sampled. The valid
values are "Ingress", "Egress", or "Both". The default value is "Both".
PollPorts (optional)
Specifies a list of VC enet module ports whose polling intervals are to be
modified. The ports are specified as a comma separated list where each port is
in the format:
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric-20.40 F8 Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem