HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual

Page 34

Advertising
background image

Command line 34

Item

Description

"Preferred"

->add enet-connection MyProfile Network=MyNetwork

SpeedType=Custom Speed=2000

Adds a new Ethernet network connection and sets the speed to 2Gb

->add enet-connection MyNewProfile

Network=SomeNetwork McastFilter=MyFilter

Adds a new Ethernet network connection with an associated McastFilter

->add enet-connection MyNewProfile

Network=SomeNetwork McastFilterSet=MyFilterSet

Adds a new Ethernet network connection with an associated McastFilter

Set

Item

Description

remove enet-connection

Remove the last Ethernet network connection from an existing server

profile.

Syntax

remove enet-connection <ProfileName>

Parameter

ProfileName (required)

The name of the profile from which the Ethernet connection is removed

Example

->remove enet-connection MyProfile

Removes an Ethernet network connection from a profile

Item

Description

set enet-connection

Modify an Ethernet connection of a server profile.

Syntax

set enet-connection <ProfileName> <Port>

[Network=<NetworkName>][McastFilter=<McastFilterName

>|McastFilterSet=<McastFilterSetName>

[PXE=<enabled|disabled|UseBios>]

[SpeedType=<Auto|Preferred|Custom|Disabled>]

[Speed=<speed>]

Parameters

ProfileName (required)

The name of the server profile that contains the connection to modify

Port (required)

The port number of the connection being modified

Properties

Network (optional)

The name of the Ethernet network to associate with the connection. This

applies to Ethernet network connections only. A blank string makes the
Ethernet connection unassigned.

McastFilter (optional)

The name of the Multicast Filter to associate with the connection if the

Multicast Filter name has not been specified.

McastFilterSet (optional) The name of the Multicast Filterset to associate with the connection if the

Multicast Filterset name has not been specified.

PXE (optional)

Enables or disables PXE on a connection. Valid values are "enabled",

"disabled", and "UseBios". This applies to Ethernet network connections

only.
PXE can be enabled on one connection per profile.

SpeedType (optional)

The requested operational speed for the server port. Valid values include

"Auto", "Preferred", "Custom", and "Disabled". The default value is
"Preferred".

If the speed type is "Auto", the maximum port speed is determined by the

maximum configured speed for the network.

If the speed type is "Preferred", the speed of the network is the same as the

Advertising