Command line 114

Item

Description

show sflow-receiver

Display the receiver name.

Syntax

show sflow-receiver [<ReceiverName|*>]

Parameter

ReceiverName

(optional)

The name of an existing sflow receiver in the domain. A receiver name of "*"
displays all the receivers.

Examples

->show sflow-receiver

Displays the sflow receiver

snmp-access

Manage SNMP access.
Supported actions: add, help, remove, show

Item

Description

add snmp-access

Add new ranges of IP addresses that will be permitted to access VC Ethernet

modules through the SNMP interface.

Syntax

add snmp-access Network=<IP Address/Netmask Bits>

Parameter

Network (required)

The network IP address in the format IP Address/Netmask Bits. The IP

address must be unique and the starting address of an IP subnet range.

Example

->add snmp-access Network=192.168.0.0/24

->add snmp-access Network=2001::1/64

Adds a new range(s) of IP addresses

Item

Description

remove snmp-access

Remove already configured range(s) of IP addresses that were permitted to
access VC Ethernet modules through the SNMP interface.

Syntax

remove snmp-access Network=<IP Address> | *

Parameter

Network (required)

The network IP address of a configured SNMP access

Examples

->remove snmp-access Network=192.168.0.0

->remove snmp-access Network=2001::1

Removes a range(s) of IP addresses

->remove snmp-access *

Removes all configured ranges of IP addresses

Item

Description

show snmp-access

Display the ranges of IP addresses that are already configured to access VC

Ethernet modules using the SNMP interface.

Syntax

show snmp-access

Example

->show snmp-access

Displays all configured ranges of IP addresses