Attributes, Actions, Fxsa / fx2sa (servernet/fx / servernet/fx2) – HP NonStop G-Series User Manual
Page 121: Fxsa / fx2sa

be up to four Fiber SACs on each ServerNet/DA CRU.
Location in OSM Tree: System > Group > Module > SNDA > FSAC
Example: FSAC (11.1.53.1)
Attributes
FSAC
Service State
Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK.
Physical
Track ID
The track ID of the switch logic board.
Part Number
The part number of the switch logic board.
Hardware Revision The hardware revision of the switch logic board.
CRU Type
The type of CRU this SAC is connected to.
Values: SSAC, FSAC, SCSI
Logical
Configured Type
The type of storage device supported by this Fiber SAC.
Values: Disk, Tape, SCSI Controller, Not Configured, Unknown
Actions
Responsive Test
Verifies that the component is connected and responding.
FXSA / FX2SA (ServerNet/FX / ServerNet/FX2)
The ServerNet/FX adapter (FXSA) and ServerNet/FX 2 adapter (FX2SA) field-replaceable units
(FRUs) allow NonStop S-series servers to communicate with NonStop K-series servers using a
fiber-optic ring.
Location in OSM Tree: System > Group > Module > FX2SA
Slot Location: FXSA and FX2SA FRUs can be installed in slots 51 through 54 in PMF or IOMF
enclosures (service side).