Actions, Blower (disk drive enclosure), Attributes – HP NonStop G-Series User Manual

Page 80: Fan (disk drive enclosure)

Advertising
background image

Current Value

The current combined voltage of both the upper and lower cells of the
battery.

If the Total Voltage falls below 42 volts, an alarm is generated.

If the Total Voltage falls below the 39.6 volts, the battery is
disconnected.

Normal Maximum Value The maximum voltage that the battery can hold (60 volts).

Actions

Enable/Disable

Prepares the battery to supply power when AC power is unavailable. The battery must be enabled to
remain charged.

Parameter: Enabled (true = enabled, false = disabled)

Blower (Disk Drive Enclosure)

Attributes

Actions

This object represents a Blower, a subcomponent of a

Disk Drive Enclosure

.

There are two blowers in each enclosure. Each blower is mounted on a power supply and cools the
enclosure by circulating air through the enclosure and the elements. The rate at which air moves (the
air flow) determines the amount of cooling and is a function of blower speed (rpm). These blowers,
under the control of the EMU or the associated power supply, can operate at multiple speeds. This
ensures that when the enclosure temperature changes the blowers can automatically adjust the air
flow.

Location in OSM Tree: System > Group > Daisy Chained Disk Drive Enclosure > Disk Drive
Enclosure > Fan

Example: Fan (111.211.1.97)

Attributes

Fan

Service State

Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK.

Values

Physical

Part Number

The part number of the component that was assigned in manufacturing. Use
part numbers for identifying and ordering parts.

Advertising