Actions – HP NonStop G-Series User Manual

Page 204

Advertising
background image

SCSI Controller

The number (3) that identifies the SCSI controller that manages the tape
drive.

Example: SSAC (1.1.55.3)

Configured
Controller Location

The location of the SCSI controller.

Example: IOMF2.SAC-3.GRP-1.MOD-1.SLOT-55

Actions

Responsive Test

Verifies that the component is installed and responding.

Start

Puts the tape process in a state to accept regular I/O commands to the tape drive. When the Start
action completes, the drive is in the Started state.

Note that Start is a logical command and does not affect the hardware.

Stop

Puts the tape process in a state to disallow regular I/O commands to the tape drive. When the Stop
action completes, the tape drive is in the Stopped state.

Note that Stop is a logical command and does not affect the hardware.

Switch Process Pair

Switches processors of the primary and backup tape I/O processes.

Test Extended

Tests vary depending on the type of tape drive. This table lists the actions performed for each
supported tape device (listed by Product ID).

Product ID

Actions Performed

CT9840

N/A (The action can be initiated, but it will perform the same tests done by the Test
Verify action.)

T514x

Data loopback test

Drum motor test

Servo interface loopback test