Internal servernet fabric, Attributes, Actions – HP NonStop G-Series User Manual

Page 134: Ioam (i/o adapter module), Groups. use the, Group connectivity servernet path test, Ioam, I/o adapter module, Enclosures. for more, Adapter module

Advertising
background image

Internal ServerNet Fabric

Attributes

Actions

The system has two internal ServerNet fabric objects, the Internal ServerNet X Fabric and the
Internal ServerNet Y Fabric. These objects can be expanded in the tree pane to see the Processor
Switch components assocuated with each fabric.

Location in OSM Tree: Under System

Example: Internal ServerNet Y Fabric

Attributes

Internal ServerNet Y Fabric

Service State

Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK.

Values

Actions

Group Connectivity ServerNet Path Test

You can perform this action on either the Internal ServerNet X Fabric or the Internal ServerNet Y
Fabric. The action tests the links between SPs and ServerNet Switch Board maintenance entities
(MEs) that provide ServerNet communication between groups on the system.

Start ServerNet

Starts all ServerNet traffic through all or specified processors on the fabric.

Stop ServerNet

Stops all ServerNet traffic through all or specified processors on the fabric.

IOAM (I/O Adapter Module)

Attributes

Actions

A modular I/O adapter module. There are two IOAMs in each

IOAM Enclosure

.

Each IOAM contains:

A

ServerNet Switch Board