Actions – HP NonStop G-Series User Manual

Page 141

Advertising
background image

Rail Maximum Voltage

The maximum voltage limit (60 volts) for the CRU.

Other Rail Voltage After Fuse

The current voltage on the Other Rail of the PMF2 CRU, measured
after the fuse.

DCC Voltage

The operational voltage of the PMF or IOMF2 CRU (specifically,
the raw voltage supplied to the DC-to-DC converters).

Other Rail Voltage

The voltage of the Other Rail, which connects the PMF/IOMF CRU
to the other power supply in the enclosure (to provide power in the
event of a problem with the Main Rail power supply).

Storage ASIC

Initialization State

The status of the storage ASIC in the CRU.

Values: Initialized, Uninitialized, Unknown

Actions

Disable ServerNet Port

Disables the specified ServerNet port on this CRU. Perform this action only as directed by OSM
alarm repair actions.

Parameter: Port Number

Enable ServerNet Port

Enables the specified ServerNet port on this CRU. Perform this action only as directed by OSM
alarm repair actions.

Parameter: Port Number

Force Power Off

This action is not supported for this CRU type. See the

Prepare to Power Off

action.

Power Off

This action is not supported for this CRU type. See the

Prepare to Power Off

action.

Prepare to Power Off

Performs precautionary check to make sure that you can safely remove the CRU.

The precautionary check makes sure that the other IOMF2 CRU in this enclosure exists and is
powered on.

If the check confirms that you can safely power off the CRU, these preparatory steps are performed:

If the SP on this IOMF2 is designated as Active (Primary), resets the SP so that the peer SP