Attributes – HP NonStop G-Series User Manual

Page 140

Advertising
background image

One external

SSAC

A ServerNet plug-in card (

PIC

), which provides connectivity to

internal ServerNet fabrics

Location in OSM Tree: System > Group > Module > IOMF2

Slot Location: IOMF2 CRUs are located in slots 50 and 55 of S-series I/O enclosures (service side).

Example: IOMF2 (1.1.55)

Attributes

IOMF2

Service State

Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK.

Values

Physical

Power State

Whether the component is powered on.

Values

Part Number

The part number of the component that was assigned in manufacturing. Use
part numbers for identifying and ordering parts.

Track ID

A unique serial number that identifies the component. Track IDs are used for
tracking components.

Hardware Revision

A code that identifies the generation of the component. Hardware revision
codes are used for tracking components.

Logical

Fan Voltage

The current voltage of the Fan CRU.

Main Rail Voltage

The voltage of the Main Rail, which supplies power to the CRU
from its own power supply

Disabled ServerNet Ports

Which, if any, ServerNet router ports on this CRU are disabled.
OSM actions to disable or enable a ServerNet port are performed as
directed by OSM alarm repair actions.

SCSI-Y Voltage

The voltage of the SCSI-Y path, the path configured for mirrored
disks on a system.

MOSFET Voltage

The voltage measured between the MOSFET switch and the diode to
the DCC. The MOSFET switch is located on the Other Rail between
the alternate power supply and the DCC.

Rail Minimum Voltage

The minimum voltage (39.6 volts) that must be available to power
the CRU.

Main Rail Voltage After Fuse

The current voltage on the Main Rail of the PMF2 CRU, measured
after the fuse.

SCSI-X Voltage

The voltage of the SCSI-X path, the primary path used for disks on a
system.

Advertising