Power Supply

Attributes

Actions

Replacement Guidelines and Precautions

The power supply converts standard AC line voltage and distributes DC power to all components in
its power domain. The power supply is:

A component of all the

IOMF

CRUs and

PMF

CRUs in NonStop S7000 servers

A separate CRU for enclosures containing

IOMF2

,

PMF2

, or PMF CRUs in NonStop S7400

or later servers

In Telco systems, the power supply units displayed in slots 31 and 32 of the OSM GUI
represent up to 4 Telco Isolating Converters (TICs) in positions A1, A2, B1, and B2. For
information on installing or replacing power components in a Telco system, see the NonStop
S-Series Central Office Server Installation and Service Guide
.

Location in OSM Tree:

Component: System > Group > Module > CRU > Power Supply

CRU: System > Group > Module > Power Supply

Slot Location:

Component: Power supplies are located within NonStop S7000 PMF CRUs and within IOMF CRUs
in slots 50 and 55 of the enclosure (service side).

CRU: Power supply CRUs are located in slots 31 and 32 of enclosures containing IOMF2, PMF2,
and PMF (NonStop S7400 or later) CRUs.

Example: Power Supply (1.1.31)

Attributes

Power Supply

Service State

Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK.

Values

Physical

Power State

The state of the power supply CRU as known to the operating system on the server.

Values

Logical