Attributes, Actions, Pmf (processor multifunction) – HP NonStop G-Series User Manual

Page 155: A component of

Advertising
background image

Example: PMCU (1.1.21)

Attributes

PMCU

Service State

Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK.

Values

Physical

Power State

Whether the component is powered on.

Values

Part Number

The part number of the component that was assigned in manufacturing. Use
part numbers for identifying and ordering parts.

Track ID

A unique serial number that identifies the component. Track IDs are used for
tracking components.

Hardware Revision

A code that identifies the generation of the component. Hardware revision
codes are used for tracking components.

Temperature Sensor

Normal Minimum Value

The minimum acceptable air intake temperature is 5 degrees Celsius. If
the temperature falls below 5 degrees, an alarm is generated.

Current Value

The current temperature, in degrees Celsius (°C), inside the enclosure of
the module.

Normal Maximum Value

The maximum acceptable air intake temperature is 50 degrees Celsius. If
the temperature rises above 50 degrees, an alarm is generated.

Actions

None.

PMF (Processor Multifunction)

Attributes

Actions

Each processor multifunction (PMF) CRU in a NonStop server contains these components:

A processor and memory board (PMB), which contains a

processor

A

power supply

(S7000 only)

A

service processor (SP)

Three

SCSI controllers