3-6 Compaq Integrated Smart Array Controller User Guide

Compaq Confidential – Need to Know Required

Writer: CDresden Project: Compaq Integrated Smart Array Controller User Guide Comments:

Part Number: 153236-001 File Name: d-ch3 Updating Firmware.doc Last Saved On: 8/26/99 3:33 PM

9. Review the information on the Caution screen:

Device to reprogram:

COMPAQ Integrated Smart Array Controller

Current ROM revision:

COMPAQ Integrated Smart Array Controller x.xx

Selected ROM revision:

COMPAQ Integrated Smart Array Controller y.yy

10. Perform one of the following steps:

G

Press Esc to discontinue the reprogramming and return to the Select
An Image screen.

OR

G

Press Enter to reprogram the Integrated Smart Array Controller
ROM. The following onscreen message indicates that the Integrated
Smart Array Controller ROM is being reprogrammed.

CAUTION: Do not interrupt the reprogramming cycle. Interrupting the ROM
reprogramming will leave the firmware in an unknown state. If this happens,
you may not be able to reprogram the ROM, and the Integrated Smart Array
Controller ROM may have to be replaced. You will be notified when
reprogramming is completed.

11. When the Options ROMPaq has finished reprogramming the Integrated

Smart Array Controller ROM, do one of the following:

G

Press Enter to reprogram another Compaq option, and repeat
steps 5 through 10.

OR

G

Press Esc to exit the ROMPaq Utility.

12. After exiting the ROMPaq Utility, remove the Options ROMPaq

diskette and restart the server by cycling the power or performing a cold
start.

The Integrated Smart Array Controller ROM is now reprogrammed and allows
you to take advantage of new or increased capabilities available with the new
firmware.