HP Compaq Integrated Smart Array Controller User Manual

Page 92

Advertising
background image

6-24 Compaq Integrated Smart Array Controller User Guide

Compaq Confidential – Need to Know Required

Writer: CDresden Project: Compaq Integrated Smart Array Controller User Guide Comments:

Part Number: 153236-001 File Name: g-ch6 Compaq Array Configuration Utility.doc Last Saved On: 8/27/99 11:25 AM

Grouping Physical Drives
of the Same Size into an Array

This procedure creates two new arrays: Array B and Array C. Array A
contains the operating system and will not be used or modified.

1. In the Controller Selection frame, select the Smart Array Controller,

Embedded Slot.

2. Select the Create Array button. The Create Drive Array screen is

displayed.

Figure 6-19. Create Drive Array screen

3. Select the four 9.1-GB drives you want to use in array B from the drives

listed in the Existing Drives frame.

NOTE: Always group physical drives of the same size. The Integrated Smart Array
Controller treats all the drives as the same size as the smallest drive in the same array. If
you mix drive sizes, the capacity of the largest drive is wasted.

For this example select the following drives:

Port 2:SCSI ID 0
Port 2:SCSI ID 1
Port 2:SCSI ID 2

Advertising