Installing the Operating System Drivers 5-25

Compaq Confidential – Need to Know Required

Writer: CDresden Project: Compaq Integrated Smart Array Controller User Guide Comments:

Part Number: 153236-001 File Name: f-ch5 Installing the Operating System Drivers.doc Last Saved On: 8/26/99 8:12 PM

/I Ignore

The Ignore command line instructs the controller to ignore the specified
adapter, bypass controlling the adapter with the specified drive, or
prevent the ADD driver from recognizing the specified adapter. Use this
command to allow another driver to control the specified adapter.

CAUTION: Do not use this command line to ignore the primary, or boot,
controller. If the boot controller is ignored, your server will not start.

Ignore command line example:

The following statement prevents the ADD driver from claiming
adapter 2:

BASEDEV=CPQARRAY.ADD /A:2 /I

This example applies when you are running NetWare on your OS/2 2.x
system and you want a NetWare NLM to control adapter 2 instead of
configuring the ADD driver to control adapter 2.