HP XP Continuous Access Software User Manual

Page 154

Advertising
background image

M-R Path: The type of channel interface between the local and the remote storage systems.
This column displays Fibre.

Minimum Paths: The minimum possible number of paths between the local and the remote
storage systems.

RIO MIH Time: The RIO MIH timer value, which is the wait time until a data transfer from the
local storage system to the remote storage system is complete.

DKC Registered: The date and time when the local and the remote storage systems are
associated with each other.

Last Updated: The date and time when the last operation on a logical path to the remote
storage system was performed.

Refresh the DKC Operation tab after this window is closed:If you select this check box,
information in the DKC Operation window refreshes after you close the DKC Status window.

Refresh: Refreshes the information in the DKC Status window.

Close: Closes the DKC Status window.

Table 34 Logical Path Status

Remarks

Status

This path has been successfully established and can be used for XP Continuous
Access Journal remote copy activities.

Normal

An operation for configuring or deleting this logical path is in progress.

Nothing

An error occurred with the initialization of a connection between the local and the
remote storage systems. The probable causes are:

No cable is connected to the local storage system.

No cable is connected to the remote storage system.

No cable is connected to the network device between the local and the remote
storage systems.

Initialization Failed

This indicates one of the following statuses:

A timeout error has occurred between the primary and the secondary storage
systems.

A logic error was detected between the primary and the secondary storage
systems.

Communication
Timeout

The local storage system rejected the function for configuring a logical path
connection. All logical path resources in the local storage system might be used
for other connections.

Resource Shortage
(Port)

The remote storage system rejected the function for configuring a logical path
connection. All logical path resources in the remote storage system might be used
for other connections.

Resource Shortage
(Pair-Port)

The serial number of the storage system connected to this logical path does not
match the serial number specified in theAdd DKC window.

Serial Number
Mismatch

The port is not an initiator port.

Invalid Port

This indicates one of the following statuses:

The specified port number is incorrect.

The port in the remote storage system is physically disconnected from the local
storage system.

Pair-Port Number
Mismatch

The port on the remote storage system is not an RCU target port.

Pair-Port Type
Mismatch

A communications timeout error has occurred on the path between the primary
and the secondary storage systems.

Communication Failed

154 Configuring Storage Systems and Logical Paths

Advertising
This manual is related to the following products: