Vaisala WXT510 User Manual

Page 122

Advertising
background image

User’s Guide ______________________________________________________________________

120 _________________________________________________________________ M210470EN-D

0xUabc!0TX,Use chksum CCb<cr><lf> (wrong checksum applied to
the 0xU command)

See also

Chapter 10, Troubleshooting, on page 117

. In case of constant

error, please contact Vaisala Service Center, see

Vaisala Service

Centers on page 115

.

Table 10

Error Messaging/Text Messages Table

Text message identifier (in
NMEA 0183 v3.0 protocol only)

Text Message

Interpretation and action

01

Unable to measure error

The requested parameters are
not activated in the message,
see

Chapter 8, Sensor and Data

Message Settings, on page 93

,

and check the parameter
selection fields.

02

Sync/address error

The device address in the
beginning of the command is
invalid. Ask the device address
with the ?! (SDI-12) or ?<cr><lf>
(ASCII and NMEA) command
and retype the command with
the correct address.

03

Unknown cmd error

The command is not supported,
use the correct command format,
see

Chapter 7, Getting the Data

Messages, on page 53

.

04

Profile reset

Checksum error in configuration
settings during power-up.
Factory settings used instead.

05

Factory reset

Checksum error in calibration
settings during power-up.
Factory settings used instead.

06

Version reset

New software version in use.

07

Start-up

Software reset. Program starts
from the beginning.

08

Use chksum xxx

Given checksum not correct for
the command. Use the proposed
checksum.

09

Measurement reset

The ongoing measurement of all
the sensors interrupted and
started from the beginning.

10

Rain reset

The precipitation sensor counter
reset.

11

Inty reset

Precipitation sensor intensity
counter reset.

Advertising