Composite data message query (ar0) – Vaisala WXT510 User Manual

Page 65

Advertising
background image

Chapter 7 __________________________________________________ Getting the Data Messages

VAISALA _______________________________________________________________________ 63

Example of the response:

0R1,Dm=027D,Sm=0.1M<cr><lf>

0R2,Ta=74.6F,Ua=14.7P,Pa=1012.9H<cr><lf>

0R3,Rc=0.10M,Rd=2380s,Ri=0.0M,Hc=0.0M,Hd=0s,
Hi=0.0M<cr><lf>

0R5,Th=76.1F,Vh=11.5N,Vs=11.5V,Vr=3.510V<cr><lf>

Composite Data Message Query
(aR0)

This command is used to request a combined data message with user
configurable set of wind, pressure, temperature, humidity, precipitation
and supervisor data.

Command format: aR0<cr><lf>

Example of the response (the parameters included can be chosen
from the full parameter set of the commands aR1, aR2, aR3 and
aR5):

0R0,Dx=005D,Sx=2.8M,Ta=23.0C,Ua=30.0P,Pa=1028.2H,
Hd=0.00M,Rd=10s,Th=23.6C<cr><lf>

For selecting the parameter set in the response message, see

Chapter 8,

Sensor and Data Message Settings, on page 93

.

where
a

=

Device address (default = 0)

R

=

Combined message query command

<cr><lf>

=

Command terminator

where
a

=

Device address

R0

=

Composite data message query command

<cr><lf>

=

Command terminator