Vaisala WXT510 User Manual

Page 38

Advertising
background image

User’s Guide ______________________________________________________________________

36 __________________________________________________________________ M210470EN-D

In most occasions the average consumption is less than 10 mA.
Typically, the higher the voltage the lower the current, but with voltages
above 18 V the current will gradually increase, adding to the usual
consumption an extra 4 mA at 24 V (see

Figure 14 on page 36

).

0505-202

Figure 14

Average Operational Current Consumption (with
4Hz Wind Sensor Sampling)

Heating voltage Vh+ (one of the following three alternatives):

-

5 ... 30 VDC;

-

AC, max V

peak-to-peak

84 V (= 30 V

RMS

); or

-

Full-wave rectified AC, max V

peak

42 V (= 30 V

RMS

).

The recommended DC voltage ranges are as follows:

-

12 VDC ± 20 % (max 1.1 A);

-

24 VDC ± 20 % (max 0.6 A).

At approximately 16 V heating voltage level WXT510 automatically
changes the heating element combination in order to consume equal
power with 12 VDC and 24 VDC supplies. Input resistance (R

in

) is

radically increased with voltages above 16 V (see the following graph).

The recommended ranges for AC or full-wave rectified AC are:

-

68 V

p-p

± 20 % (max 0.6 A), for AC;

-

34 V

p

± 20 % (max 0.6 A), for f/w rectified AC.

Advertising