User’s Guide ______________________________________________________________________

62 __________________________________________________________________ M210470EN-D

Supervisor Data Message (aR5)

With this command you can request a supervisor data message
containing self-check parameters of the heating system and power
supply voltage.

Command format: aR5<cr><lf>

Example of the response (the parameter set is configurable):

0R5,Th=25.9C,Vh=12.0N,Vs=15.2V,Vr=3.475V<cr><lf>

To change the parameters and units in the response message and to
make other settings, see section

Supervisor Message on page 108

.

Combined Data Message (aR)

With this command you can request all individual messages aR1, aR2,
aR3 and aR5 with just one command.

Command format: aR<cr><lf>

where
a

=

Device address

R5

=

Supervisor message query command

<cr><lf>

=

Command terminator

where
a

=

Device address

R5

=

Supervisor message query command

Th

=

Heating temperature (C = °C)

Vh

=

Heating voltage (N = heating is off)

Vs

=

Supply voltage (V = V)

Vr

=

3.5 V reference voltage (V = V)

<cr><lf>

=

Response terminator