Vaisala WXT510 User Manual

Page 52

Advertising
background image

User’s Guide ______________________________________________________________________

50 __________________________________________________________________ M210470EN-D

Example (ASCII and NMEA 0183, device address 0):

0XU<cr><lf>

0XU,A=0,M=P,T=0,C=2,I=0,B=19200,D=8,P=N,S=1,L=25,
N=WXT510,V=1.00<cr><lf>

Example (SDI-12, device address 0):

0XXU!0XXU,A=0,M=S,T=0,C=1,I=0,B=1200,D=7,P=E,S=1,L=25,
N=WXT510,V=1.00<cr><lf>

[L]

=

RS-485 line delay: 0 ... 10000 ms
Defines the delay between the last character of the
query and the first character of the response message
from WXT510. During the delay, the WXT510's
transmitter is disabled. Effective in ASCII, polled
and NMEA 0183 query protocols. Effective when
RS-485 is selected (C = 3).

[N]

=

Name of the device: WXT510 (read only)

[V]

=

Software version: for example, 1.00 (read only)

<cr><lf>

=

Response terminator

NOTE

There are two different SDI-12 modes available for providing all the
functionality of the SDI-12 v1.3 standard.

The lowest power consumption is achieved with the Native SDI-12
mode (aXU,M=S), as it makes measurements and outputs data only on
request.

In the continuous SDI-12 mode (aXU,M=R) internal measurements
are made at a user-configurable update interval, see

Chapter 8, Sensor

and Data Message Settings, on page 93

. The data is outputted on

request.

Advertising