Inputs and outputs, Operating conditions, Inputs and outputs operating conditions – Vaisala WXT510 User Manual

Page 128: Table 16 inputs and outputs, Table 17 operating conditions

Advertising
background image

User’s Guide ______________________________________________________________________

126 _________________________________________________________________ M210470EN-D

Inputs and Outputs

Operating Conditions

Table 16

Inputs and Outputs

Property

Description/Value

Operation voltage

5 ... 30 VDC

1

1. Below 5.3 V the measurement performance for high wind speeds may be

degraded.

Average power consumption
minimum

0.07 mA @ 12 VDC (SDI-12)

typical

3 mA @ 12 VDC (with default measuring
intervals)

maximum

13 mA @ 30 VDC (constant measurement
of all parameters)

Heating voltage

Options: DC, AC, full-wave rectified AC

recommended ranges

12 VDC ± 20 %, 1.1 A max
24 VDC ± 20 %, 0.6 A max
68 V

p-p

± 20 % (AC), 0.6 A

rms

max

34 V

p

± 20 % (f/w rect. AC), 0.6 A

rms

max

absolute max

30 VDC
84 V

p-p

(AC)

42 V

p

(f/w rect. AC)

Digital outputs

SDI-12, RS-232, RS-485, RS-422

Communication protocols

SDI-12 v1.3, ASCII automatic & polled,
NMEA 0183 v3.0 with query option

Table 17

Operating Conditions

Property

Description/Value

Housing protection class

IP55

Temperature
operation

-52 ... +60 °C (-60 ... +140 °F)

storage

-60 ... +70 °C (-76 ... +158 °F)

Relative humidity

0 ... 100 %RH

Pressure

600 ... 1100 hPa

Wind

0 ... 60 m/s

Electromagnetic compatibility

EN61326: 1997 + Am 1:1998 + Am2:2001
Electrical equipment for measurement,
control and laboratory use - EMC
requirements; Generic environment