User’s Guide ______________________________________________________________________

76 __________________________________________________________________ M210470EN-D

Example 3:

Start a precipitation measurement and request the data:

0M3!00006<cr><lf> (6 parameters available immediately, thus the
device address is not sent)

0D0!0+0.15+20+0.0+0.0+0+0.0<cr><lf>

Example 4:

Start a supervisor measurement with CRC and request the data:

0MC5!00014<cr><lf> (measurement ready in one second and 4
parameters available)

0<cr><lf> (measurement completed)

0D0!0+34.3+10.5+10.7+3.366DpD<cr><lf>

Example 5:

Start a composite measurement and request the data. The configuration
of the parameter set is such that nine (9) parameters are available. Thus
start measurement command aM can be used. Due to the 35-character
limit in response message, aD0 returns only six parameters. The
remaining parameters are retrieved with aD1.

0M!00059<cr><lf> (measurement ready in 5 seconds and 9
parameters available)

0<cr><lf> (measurement completed)

0D0!0+340+0.1+23.7+27.9+1009.3+0.15<cr><lf>

0D1!0+0.0+0+0.0<cr><lf>

Example 6:

Start a composite measurement and request the data. The configuration
of the parameter set is such that 20 parameters are available. Thus Start
concurrent measurement command aC shall be used. Due to the 75-
character limit in response message, aD0 returns only 14 parameters.
The remaining parameters are retrieved with aD1.

0C!000520<cr><lf> (measurement ready in 5 seconds and 20
parameters available)