Table 14 wind – Vaisala WXT510 User Manual
Page 126
User’s Guide ______________________________________________________________________
124 _________________________________________________________________ M210470EN-D
0505-209
Figure 21
Accuracy Over Temperature Range
Table 13
Relative Humidity
Property
Description/Value
Range
0 ... 100 %RH
Accuracy
±3 %RH at 0 ... 90 %RH
±5 %RH at 90 ... 100 %RH
Output resolution
0.1 %RH
PTU Measuring interval
1 ... 3600 s (= 60 min), at one second steps
Table 14
Wind
Property
Description/Value
Wind speed
range
0 ... 60 m/s
response time
0.25 s
available variables
average, maximum, and minimum
accuracy
±0.3 m/s or ±3 % whichever is greater for
the measurement range of 0 ... 35 m/s
±5 % for the measurement range of
36 ... 60 m/s
output resolution
0.1 m/s (km/h, mph, knots)
units available
m/s, km/h, mph, knots
Wind direction
azimuth
0 ... 360°
response time
0.25 s
available variables
average, maximum, and minimum
accuracy
±3.0°
output resolution
1°
°C
°C
-0.7
0.7
0.6
0.5
0.4
0.3
0.2
0.1
-0.1
-0.2
-0.3
-0.4
-0.5
-0.6
0
0
-60
-40
-20
20
40
60
80
-80