Communication Setting Commands

Checking the Current
Communication Settings (aXU)

With this command you can request the current communication settings
of WXT510.

Command format in ASCII and NMEA 0183: aXU<cr><lf>

Command format in SDI-12: aXXU!

Example response in ASCII and NMEA 0183:

aXU,A=a,M=[M],T=[T],C=[C],I=[I],B=[B],D=[D],P=[P],S=[S],
L=[L],N=[N],V=[V]<cr><lf>

Example response in SDI-12:

aXXU,A=a,M=[M],T=[T],C=[C],I=[I],B=[B],D=[D],P=[P],S=[S],
L=[L],N=[N],V=[V]<cr><lf>

NOTE

Hereafter the commands to be typed are presented in normal text while
the responses of the transmitter are presented in italic.

where
a

=

Device address, which may consist of the following
characters: 0 (default) ... 9, A ... Z, a ... z.

XU

=

Device settings command in ASCII and NMEA 0183

XXU

=

Device settings command in SDI-12

<cr><lf>

=

Command terminator in ASCII and NMEA 0183

!

=

Command terminator in SDI-12