Start measurement command (am) – Vaisala WXT510 User Manual

Page 72

Advertising
background image

User’s Guide ______________________________________________________________________

70 __________________________________________________________________ M210470EN-D

The response:

a13ccccccccmmmmmmvvvxxxxxxxx<cr><lf>

Example:

0I!013VAISALA_WXT510103Y2630000<cr><lf>

Start Measurement Command (aM)

This command asks the device to make a measurement. The measured
data are not sent automatically and should be requested with a separate
Send data command aD.

The host device is not allowed to send any commands to other devices
on the bus until the measurement is completed. When several devices
are connected to the same bus and simultaneous measurements from the
different devices are needed, Start concurrent measurement aC or Start
concurrent measurement with CRC aCC should be used, see the next
sections.

See

Examples of aM, aC and aD Commands on page 75

.

where
a

=

Device address

I

=

Send identification command

!

=

Command terminator

where
a

=

Device address

13

=

The SDI-12 version number, indicating SDI-12
version compatibility; for example, version 1.3 is
encoded as 13

cccccccc

=

8-character vendor identification Vaisala_

mmmmmm =

6 characters specifying the sensor model number

vvv

=

3 characters specifying the firmware version

xxxxxxxx

=

8-character serial number

<cr><lf>

=

Response terminator