MagTek MagneSafe V5 User Manual

Page 112

Advertising
background image

MagneSafe V5

104

Response : RC= 00, LEN=0A, DATA=FF FF 98 76 54 32 10 E0 00 02

15 00 ; Get current Security Level (Should be 04)
Request : CMND=15, LEN=00, DATA=
Response : RC= 00, LEN=01, DATA=04


Example 8: Changing from Security Level 3 to Security Level 4:

; This script demonstrates changing from Security Level 3 to Security Level 4.
; It assumes the reader is at Security Level 3 with the ANSI X9.24 Example
; key loaded and the KSN counter set to 2.
09 00 ; Get current KSN (should be FFFF9876543210E00002)
Request : CMND=09, LEN=00, DATA=
Response : RC= 00, LEN=0A, DATA=FF FF 98 76 54 32 10 E0 00 02

; For KSN 2, MAC Key: C46551CEF9FDDBB0 AA9AD834130DC4C7
;
; The command to change Security Level looks like: 15 05 04 nnnnnnnn
; where nnnnnnnn is the MAC.
;
; The data to be MACd is: 15 05 04
; Data to be MACd must be in blocks of eight bytes, so we left justify and
; zero fill the block to get: 15 05 04 00 00 00 00 00 (This is the block to MAC)
; For convenience show it as the compacted form: 1505040000000000
;
; The MAC algorithm run with this data uses the following cryptographic
; operations:
;
; Single DES Encrypt the data to be MACd with the left half of the MAC Key:
; 1505040000000000 1DES Enc with C46551CEF9FDDBB0 = 735323A914B9482E
;
; Single DES Decrypt the result with the right half of the MAC Key:
; 735323A914B9482E 1DES Dec with AA9AD834130DC4C7 = 390E2E2AC8CB4EE6
;
; Single DES Encrypt the result with the left half of the MAC Key:
; 390E2E2AC8CB4EE6 1DES Enc with C46551CEF9FDDBB0 = D9B7F3D8064C4B26
;
; The leftmost four bytes of the final result are the MAC = D9B7F3D8
;
; Send the MACd Set Security Level command
15 05 04 D9B7F3D8
Request : CMND=15, LEN=05, DATA=04 D9 B7 F3 D8
Response : RC= 00, LEN=00, DATA=

02 00 ; Reset so changes take effect
Request : CMND=02, LEN=00, DATA=
Response : RC= 00, LEN=00, DATA=

Delay : (waited 5 seconds)
09 00 ; Get current KSN (should be FFFF9876543210E00003)
Request : CMND=09, LEN=00, DATA=
Response : RC= 00, LEN=0A, DATA=FF FF 98 76 54 32 10 E0 00 03

15 00 ; Get current Security Level (Should be 04)
Request : CMND=15, LEN=00, DATA=
Response : RC= 00, LEN=01, DATA=04