MagTek MagneSafe V5 User Manual

Page 43

Advertising
background image

Section 2. Communications

35

Bluetooth Disconnect Message Property (BulleT Only)

Property ID:

0x0D

Property Type:

String

Length:

7 bytes

Get Property:

Yes

Set Property:

Yes

Default Value:

No string with a length of zero.

Description:

This property specifies a string to be used as part of a Bluetooth Disconnect
Message. The message is intended to give the connected host application a
warning that the reader is disconnecting. The full disconnect message consists
of the specified string followed by the character ‘-‘ (hyphen), followed by a
single character Reason Code, followed by a Carriage Return (0x0D)
character. The possible Reason Codes are:

‘T’ = Timeout
‘U’ = User Switch
‘B’ = Battery Low
‘S’ = Card Swipe
‘R’ = Reset command
‘I’ = Interface changed

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled for these changes to take effect.


Track Data Transmission Delay Property (Flash Only)

Property ID:

0x0D

Property Type:

Word

Length:

2 bytes

Get Property:

Yes

Set Property:

Yes

Default Value:

50 (500 milliseconds)

Description:

This property specifies, in units of 10 milliseconds, the amount of delay from
responding to a Read Oldest Transaction command until the requested Track
Data is sent.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect. This
reader must be unplugged for at least 30 seconds to properly power cycle it.


Example Set Track Data Transmission Delay property to 6 seconds Request (Hex):

Cmd Num

Data Len

Prp ID

Prp Value

01

03

0D

02 58