Section 2. Communications

45

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled for these changes to take effect.


Example Set property Request (Hex):

Cmd Num

Data Len

Prp ID

Prp Value

01

02

1B

01 (enable JIS Type 2
decode type)

Example Set property Response (Hex):

Result Code Data Len

Data

00

00

Example Get property Request (Hex):

Cmd Num

Data Len

Prp ID

00

01

1B


Example Get property Response (Hex):

Result Code Data Len

Prp Value

00

01

01


SS JIS Type 2 Property

Property ID:

0x1C

Property Type:

Byte

Length:

1 byte

Get Property:

Yes

Set Property:

Yes

Default Value:

0x7F ‘DEL’

Description:

This character is sent as the start sentinel for cards that are encoded in the JIS
type 2 format. If the value is in the range 0 – 127 then the equivalent ASCII
character will be sent.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled for these changes to take effect.