Track id enable property – MagTek MagneSafe V5 User Manual

Page 38

Advertising
background image

MagneSafe V5

30

Example Get MagneSafe Version Number property Request (Hex):

Cmd Num

Data Len

Prp ID

00

01

04


Example Get MagneSafe Version Number property Response (Hex):

Result Code Data Len

Prp Value

00

03

56 30 35


Track ID Enable Property

Property ID:

0x05

Property Type:

Byte

Length:

1 byte

Get Property:

Yes

Set Property:

Yes

Default Value:

0x95

Description:

This property is defined as follows:

id

0

T

3

T

3

T

2

T

2

T

1

T

1


Id

0 – Decodes standard ISO/ABA cards only

1 – Decodes AAMVA and 7-bit cards also
If this flag is set to 0, only tracks that conform to the ISO format allowed for that
track will be decoded. If the track cannot be decoded by the ISO method it will
be considered to be in error.


T

#

00 – Track Disabled

01 – Track Enabled

10 – Track Enabled/Required (Error if blank)

This property is stored in non-volatile memory, so it will persist when the unit is
power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect. This
reader must be unplugged for at least 30 seconds to properly power cycle it.


Example Set Track ID Enable property Request (Hex):

Cmd Num

Data Len

Prp ID

Prp Value

01

02

05

95


Example Set Track ID Enable property Response (Hex):

Result Code Data Len

Data

00

00


Example Get Track ID Enable property Request (Hex):

Cmd Num

Data Len

Prp ID

00

01

05

Advertising