Example Set Track Data Transmission Delay property Response (Hex):

Result Code Data Len

Data

00

00


Example Get Track Data Transmission Delay property Request (Hex):

Cmd Num

Data Len

Prp ID

00

01

0D


Example Get Track Data Transmission Delay property Response (Hex):

Result Code Data Len

Prp Value

00

02

02 58


Stay Powered After Swipe Property (BulleT, Flash, Wireless USB)

Property ID:

0x0E

Property Type:

Byte

Length:

1 byte

Get Property:

Yes

Set Property:

Yes

Default Value:

0x00 (Don’t Stay Powered)

Description:

This property controls whether the wireless reader stays powered after a good
swipe. If the property value is 0x00 (the default), the reader powers down
after a good swipe.

If the property value is 0x01, the reader stays powered after a good swipe. In
this case, the reader may be powered down by pressing and holding the User
Switch or it will go off after the activity timeout.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.


RF Address Property (BulleT and Wireless USB Reader)

Property ID:

0x0F

Property Type:

Binary

Length:

4 bytes

Get Property:

Yes

Set Property:

Yes

Default Value:

0x12345678

Description:

The value is a 4-byte number that represents the wireless reader’s and
dongle’s RF address. The RF address is used to pair a wireless reader to a
dongle. All reader/dongle pairs should have a different RF address from all
other reader/dongle pairs. This unique address is what allows more than one
pair to be in range of another pair without having RF commications conflict
with each other.