Es jis type 2 property – MagTek MagneSafe V5 User Manual

Page 54

Advertising
background image

MagneSafe V5

46

ES JIS Type 2 Property

Property ID:

0x1D

Property Type:

Byte

Length:

1 byte

Get Property:

Yes

Set Property:

Yes

Default Value:

0x7F ‘DEL’

Description:

This character is sent as the end sentinel for cards that are encoded in the JIS
type 2 format. If the value is in the range 0 – 127 then the equivalent ASCII
character will be sent.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled for these changes to take effect.


Pre Card String Property (KB, BulleT, UART, RS-232)

Property ID:

0x1E

Property Type:

String

Length:

0 – 7 bytes

Get Property:

Yes

Set Property:

Yes

Default Value:

No string with a length of zero.

Description:

The value is an ASCII string that represents the reader’s pre card string. This
string can be 0 – 7 bytes long. This string is sent prior to all other card data.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.


Example Set Pre Card String property Request (Hex):

Cmd Num

Data Len

Prp ID

Prp Value

01

04

1E

31 32 33


Example Set Pre Card String property Response (Hex):

Result Code Data Len

Data

00

00


Example Get Pre Card String property Request (Hex):

Cmd Num

Data Len

Prp ID

00

01

1E


Example Get Pre Card String property Response (Hex):

Result Code Data Len

Prp Value

00

03

31 32 33

Advertising