MagTek MagneSafe V5 User Manual

Page 56

Advertising
background image

MagneSafe V5

48


Example Set Pre Track String property Response (Hex):

Result Code Data Len

Data

00

00


Example Get Pre Track String property Request (Hex):

Cmd Num

Data Len

Prp ID

00

01

20


Example Get Pre Track String property Response (Hex):

Result Code Data Len

Prp Value

00

03

31 32 33


Post Track String Property (KB, BulleT, UART, RS-232)

Property ID:

0x21

Property Type:

String

Length:

0-7 bytes

Get Property:

Yes

Set Property:

Yes

Default Value:

No string with a length of zero

Description:

This string is sent after the data for each track. The string can be 0 – 7 bytes
long. If the value is 0 no character is sent.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.


Example Set Post Track String property Request (Hex):

Cmd Num

Data Len

Prp ID

Prp Value

01

04

21

31 32 33


Example Set Post Track String property Response (Hex):

Result Code Data Len

Data

00

00


Example Get Post Track String property Request (Hex):

Cmd Num

Data Len

Prp ID

00

01

21


Example Get Post Track String property Response (Hex):

Result Code Data Len

Prp Value

00

03

31 32 33

Advertising