Procedure for resetting the default CMOS setting.


The following procedure is for CP-100 consoles that have had their CMOS default settings altered.
This error can occur as a result of static shock or heavy electrical fluctuation in various environments.
The solution is possible to do without a monitor connected. However it is a darn sight easier if you
can connect one up. If you want to connect up a monitor you are going to have to have fitted a video
card. Video cards are available from your Elektralite distributor or from Elektralite direct.
SYMPTOM: The Disk Drive appears not to work.
SOLUTION: Perform the following steps.

1-

Connect a standard Windows 95 keyboard to the keyboard jack on the rear panel of the console.

2-

Power up the console.

3-

Hold the “Del.” button on the keyboard for 15 seconds.

4-

Press “Enter”

5-

Press the down arrow key 8 times.

6-

Press the “Page Up” key 2 times.

7-

Press “Esc.”

8-

Press the down arrow key 3 times.

9-

Press “Enter”

10-

Press “y”

11-

Press “Enter”

12-

Press “F10”

13-

Press “y”

14-

Press “Enter”

15-

Wait for complete reboot of the software (approximately 30 seconds)

This restores the default settings of the operating system and reconfigures it to recognize the diskette
drive.