Clearing & Resetting of Non-Volatile Memory.

The following procedure is for CP-100 consoles that have had their software corrupted.

Symptom

:

The CP-100 console will “freeze” on powering it up. It will not go to the Main Menu

screen but instead stop on the “CP100” screen.
Solution: Perform the following steps.

1. Power up the console in the normal manner. The words “Powering up…” will appear on the

display.

2. When the words “CP100” appear on the screen press the CLEAR button. You have only 1

second to do this, so be ready.

3. The board will then display the following message “ Would you like to clear the entire non-

volatile memory? Press +Yes to clear it, any other button to leave it intact.”

4. Press the +Yes button.
5. The

words

“Memory cleared” followed by “Validating software files” and then

“Successful…..loading software”.

6. The Main menu will then appear and the board will function normally.
7. Please check that your show and fixture files have not been corrupted. If they have then reload

them back into the board through the disk drive. If the disk drive appears not to be functioning
then please refer to the document “Resetting the Default CMOS settings”.