12-2-5 In

case of heating at the cooling mode or cooling at the heating mode

1. Troubleshooting

procedure

Change the setting temperature of

remote control.

Operate it with a heating mode

as soon as the defrosting is finished.

After 3 minutes, cooling

and heating start automatically.

No

No

No

Yes

Yes

Yes

Is the Thermo off?

Is the unit

in the defrosting operation?

Is the compressor

in 3 minutes off?

Check the resistance value

of 4-WAY valve coil.

Go to the next page

4-WAY valve main body error

Attach the

sensor correctly.

Over shortage

of the refrigerant

Connect the connecter

correctly.

4-WAY valve coil error

Exchange

the outdoor PCB.

No

Yes

Yes

Yes

OK

Yes

No

No

No

NG

No

Is much frost

in the indoor heat

exchanger?

Does the

4-WAY valve operate

normally?

Is the

outdoor air sensor and

outdoor heat exchanger attached

correctly?

Is the

4-WAY valve connector

connected correctly?

Dose the

voltage of AC220V

apply to the connector of 4-WAY

valve coil during the

operation?