Sunlight Supply Samsung Programmable Thermostat for Split Systems User Manual

Page 78

Advertising
background image

12-1

1

Outdoor Discharge over temperature error

Indoor display

ل

Outdoor error

Outdoor display

ƻ

م

Outdoor

Discharge

over

temperature

error

1.Checklist :
1) Check the discharge temperature in the outdoor unit
2) Check the compressor locking or gas leak
3) Download the EEPROM data

2. Troubleshooting procedure

Is the discharge over temperature

sensor error appeared again?

Terminate the service

NO

a

Ōer 30min ~ 1Hr

YES

Is the discharge over temperature

sensor error appeared again?

The condi

Ɵon is too poor for air condiƟoner to

operate

Wait un

Ɵl discharge temperature is decreased

Restart a

Ōer power oī

YES

Download the EEPROM data

Is the discharge over temperature

sensor error appeared again?

YES

Terminate the service

Terminate the service

NO

NO

Exchange the Outdoor PBA

Exchanged the Compressor

Restart a

Ōer power oī.